Product Details:
Payment & Shipping Terms:
|
| Packing: | 20tests/kit | Shelf Life: | 12 Months When Properly Stored |
|---|---|---|---|
| Sample Performance: | Fish Meat | Detection Limit: | 10 μg/kg |
Chlorpyrifos Rapid Test Card
Catalog No.: GN07AG2
1. Brief
This product is used for testing Chlorpyrifos in fish tissue qualitatively. Easy to operate with high sensitivity.
2.Specifications: 20 tests/box
3. Detection limit: 10 μg/kg
4. Application: Fish: freshwater fish, marine fish tissues.
5. Date of manufacture and batch number: See bag and outer box for details.
6. Principle
The Chlorpyrifos rapid test card applies the principle of competitive inhibition immunochromatography. During the micro-well incubation and chromatography process, Chlorpyrifos in the sample binds to the colloidal gold-labeled specific Chlorpyrifos monoclonal antibody, inhibiting the binding of the antibody to the Chlorpyrifos-BSA conjugate on the NC membrane testing line, thereby causing a change in the depth of the testing line color.
7. Components
| 1) | Chlorpyrifos rapid test card | 20 pieces |
| 2) | Microwell reagent | 20 pieces |
| 3) | Manual | 1 piece |
| 4) | Disposable dropper | 20 pieces |
| 5) | Reagent A | 1 bottle |
| 6) | Reagent B | 1 bottle |
| 7) | Reagent C | 1 bottle |
8.Auxiliary equipment
Instruments: electronic balance, centrifuge, micropipette, vortex oscillator, homogenizer.
Consumables: 50ml centrifuge tube, disposable pipette tips.
9. Sample Pretreatment
1). Take 3 ± 0.05g of homogeneous sample, place it in a 50ml centrifuge tube, add 5ml of reagent A, and then add 2g of reagent B. Shake vigorously with your hand or vortex shaker for 1 minute, centrifuge at 4000r/min for 5 minutes.
2). Transfer 3ml of supernatant to another centrifuge tube and dry it with nitrogen or air flow at 56 ℃ (or with a hair dryer).
3). Add 0.3ml of reagent C for reconstitution, shake for 30 seconds, centrifuge at 4000r/min for 5 minutes, and draw 200ul as the test solution.
10. Operation procedures
1). Please read the instructions carefully before use and restore this test card and the sample to room temperature.
2). Take out the required number of microwells and test cards, and mark them properly. Please use it as soon as possible within 1 hour. Immediately seal the remaining reagents to prevent moisture.
3). Use a micropipette to take 200 µl (or 4 drops from a dropper) of test solution and slowly aspirate multiple times into the microwells. Mix thoroughly with the freeze-dried powder in the microwells (this step is important).
4). Incubate at room temperature (20-40 ℃) for 4 minutes to complete the first step of the reaction.
5). Place the marked test card flat and use a pipette to draw 100 µl of liquid droplets from the microwells into the sample well of the test card.
6). Observe the results after allowing the reaction to stand for 5-8 minutes, and interpret the results within 1 minute according to the schematic diagram. Interpretation at other times is invalid.
11. Test Result Interpretation
1) Negative: the color of T line is darker than C line or T line has same color with C line; it means there is no Chlorpyrifos residue or the residue is lower than detection limit.
2) Positive: T line is obviously lighter than C line or T line is invisible; it means the Chlorpyrifos residue is equal to or higher than detection limit.
3) Invalid test: If C line does not show which means the test cassette is out of efficacy, out of date or improper operation. Please run the test again using another package. If the invalid tests keep happening, please contact the local distributor.
![]()
12. Precautions
1). The test card is for single use at room temperature. Never use expired test cards.
2). Disposable droppers must not be reused to avoid cross-contamination.
3). Try not to touch the white membrane surface in the center of the test card during use. Avoid direct sunlight and direct fan blowing.
4). Tap water, distilled water or deionized water cannot be used as negative controls.
5). If a positive result is detected, it is recommended to retest with this card once.
6). If you encounter any problems during the test, please contact our company.
13. Safety performance and garbage disposal
This product testing card and its packaging are non-toxic and harmless, and should be disposed of as dry waste after use; Organize samples to be treated as wet garbage.
14. Storage and expiry date
Storage: Store at 2-30℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months
Shenzhen Lvshiyuan Biotechnology Co., Ltd
D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China
Tel. 86-18165709090/86-755-28438788 Fax 86-755-28938800
Email: info@lsybt.com