Veterinary Rapid Test Device Clenbuterol rapid detection kit

China Veterinary Rapid Test Device Clenbuterol rapid detection kit supplier

Large Image :  Veterinary Rapid Test Device Clenbuterol rapid detection kit

Product Details:

Place of Origin: China
Brand Name: Green Spring
Certification: ISO9001:2008 Certificate
Model Number: LSY-20001-1

Payment & Shipping Terms:

Minimum Order Quantity: 1 kit
Price: FOBShenzhen$75/kit
Packaging Details: by cardboard box
Delivery Time: In 3 days after payment
Payment Terms: T/T or Western Union
Supply Ability: 500 kits/day
Minimum Order Quantity: 1 kit
Detailed Product Description
Highlight:

cle rapid test card

,

Clenbuterol rapid test

,

urine test card

Brand: Green Spring
Clenbuterol Residue Rapid Test Strip Catalogue No.: LSY-20001
Brief
The GreenSpring Clenbuterol Residue Rapid Inspection Device is a rapid, one step test for the qualitative detection of Clenbuterol in meat samples
Principle
The basis of the test is the antigen-antibody reaction. The one step test device is a competitive immunoassay in which the detector reagent consists of colloidal gold particles coated with affinity purified anti-Clenbuterol antibodies. The capture reagent in the assay is a Clenbuterol-protein conjugate, which is immobilised on the membrane of the test device. In the test procedure, specimens migrate over the membrane. The more analyte present in the sample, the more effectively it will compete with the Clenbuterol immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent. Clenbuterol, if present in the specimen above 3 ppb, will thus prevent the binding of the detector reagent to the Clenbuterol immobilised on the membrane, resulting in a positive result.
Specifications
NEGATIVE:
Two lines are visible and the Test Line (T) is the same as or darker than the Control Line (C), which also is the Reference Line (R). This indicates that the Clenbuterol concentration in sample is below 3 ppb.
POSITIVE:
Two lines are visible, but the Test Line (T) is lighter than the Control Line (C), or there is no Test Line. This indicates that the Clenbuterol concentration in sample is above 3 ppb.
INVALID:
Reference Line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for an invalid result. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.