LSY-20094 Avian influenza virus(AIV) antibody rapid test kit

Certification
Good quality Food Safety ELISA kit for sales
Good quality Food Safety ELISA kit for sales
I'm Online Chat Now

LSY-20094 Avian influenza virus(AIV) antibody rapid test kit

China LSY-20094 Avian influenza virus(AIV) antibody rapid test kit supplier

Large Image :  LSY-20094 Avian influenza virus(AIV) antibody rapid test kit

Product Details:

Place of Origin: China
Brand Name: Green Spring
Certification: ISO9001&ISO14001
Model Number: LSY-20094

Payment & Shipping Terms:

Minimum Order Quantity: 1 kit
Price: FOBShenzhen$100/kit
Packaging Details: By cardboard box
Delivery Time: 3 working days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 500 kits/day
Contact Now
Detailed Product Description
Shelf Life: 24 Months Sample Performance: Serum
Packing: 40 Tests/kit

 

Avian influenza virus(AIV) antibody rapid test kit

Catalog No. LSY-20094

1. Introduction

Avian influenza is caused by Orthomyxoviridae type A family specific virus. Influenza A viruses can be divided into a number of different subtypes based on hemagglutinin and neuraminidase antigenic differences.

The AIV Ab test strip is based on competitive method to detect AIV Ab in serum of poultry qualitatively, there is good sensitivity for different subtype AIV antibody. There is pre-coated antigen on test strip, AIV antibody in serum sample react with pre-coated antigen, inhibit the reaction on T line, make the T line do not appear red color. Otherwise, it appear red color.

2. Contents

1 AIV Ab test card 40 pieces
2 Dropper 40 pieces
3 AIV Ab Sample dilution 1 bottle
4 Disposable gloves 1 bag
5 Manual 1 piece

3. Test procedure

1) Collect 0.5-1ml blood, centrifuge at 3000r/min for 3-5min to separate serum. Or be static at 4℃ overnight, separate the serum naturally.

2) Take out the test card( return to room temperature firstly if store in cold), put it on desk flatly.

3) Take 30ul serum(recommend), or use dropper provided drop 1 drop of serum vertically and slowly to the sample hole with “S” mark.

4) Wait for 10min.

5) Then use the bottle with AIV Ab Sample dilution drop 2 drops to the sample hole with “S” mark.

6) There will be wine-red liquid flow the observation, wait 10-15min, the result is invalid after 15min.

 

4. Results judgment

1) Negative: control line and test line are both seen wine red, it means the antibody level lower than HI 1:16;

LSY-20094 Avian influenza virus(AIV) antibody rapid test kit

2) Positive: only control line is seen wine red, it means the antibody level equal to or higher than HI 1:32;

LSY-20094 Avian influenza virus(AIV) antibody rapid test kit

3) Invalidation: control line isn’t seen wine red.

LSY-20094 Avian influenza virus(AIV) antibody rapid test kit

5. Note

1) Do not use product with broken Aluminum foil bag package. Use test card in 1 hour after taking out.

2) If the collected serum sample can not be tested immediately, store at 4℃ for 48hours, store at below -20 ℃ for long term storage.

3) The serum sample must be clear, if there is any visible particle, centrifuge at 3000r/min for 20min to move out.

4) Add too much sample will advance reaction and lead to fault result. Same as add too much sample dilution will also lead to false result.

5) The validation of test has no relation with darkness of C line. As long as C line it clear to see, the test is valid.

6) The antigen on test card do not have potential danger, but all serum sample should be handled as local pollution properly.

7) Do not use test card out of expiry date.

 

6. Frequently asked questions

Can we use this product to quantify the antibody titer?

The detection limit of this product is HI 1:32.Therefore, by multiple proportion dilution of the tested serum, find out the maximum dilution factor when it is positive, then can get antibody titer. For example, dilute the ready to test serum sample with Saline 1:2, 1:4, 1:8 separately, then test the 3 diluted serum separately, if 1:2, 1:4 is Positive, while 1:8 is Negative, so the maximum dilution factor when it is positive is 1:4, then the antibody titer of this sample is 27(1:128) = [25(1:32) * 22 (1:4)].

 

7. Storage and expiry date

Specifications: 40T/kit

Storage: Store at 2-30 ℃.

Expiry date: 24 months; date of production is on box.

 

Shenzhen Lvshiyuan Biotechnology Co., Ltd

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788

Fax 86-755-28938800

Email: info@lsybt.com

www.lsybt.com

 

Contact Details
Shenzhen Lvshiyuan Biotechnology Co.,Ltd

Contact Person: Mrs. Bella Zou

Tel: +86-755-28438788-8030

Fax: 86-755-28938800

Send your inquiry directly to us (0 / 3000)