LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit

Certification
Good quality Animal Disease ELISA Diagnostic kit for sales
Good quality Animal Disease ELISA Diagnostic kit for sales
I'm Online Chat Now

LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit

China LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit supplier
LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit supplier LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit supplier LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit supplier

Large Image :  LSY-30043 Multiple Animal Influenza A Virus antibody ELISA Test Kit

Product Details:

Place of Origin: China
Brand Name: GreenSpring
Certification: ISO9000
Model Number: LSY-30043

Payment & Shipping Terms:

Minimum Order Quantity: 1 kit
Price: FOBShenzhen$250/kit
Packaging Details: By foam box with ice bag to maintain cool storage
Delivery Time: 3 working days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 500 kits per day
Detailed Product Description
Sample Performance: Serum Of Multiple Animal Like Swine, Birds, Dog, Horse Etc. Packing: 96wells/kit Or 192 Wells/kit
Shelf Life: 12 Months When Properly Stored

Multiple Animal Influenza A Virus antibody ELISA Test Kit

Catalog No. LSY-30043

  • Principle

Influenza virus, referred to as influenza virus, can be divided into three types: A, B, and C. Among them, influenza A virus is divided into many subtypes according to different hemagglutinin H antigen and neuraminidase N antigen. Influenza A viruses are currently known to infect a variety of animals including birds, humans, pigs, horses, dogs, whales etc.

This kit use blocking ELISA method, to detect influenza A virus antibody in serum of multiple animal like Swine, birds, dog, horse etc. When testing, add diluted serum sample, after incubation, if there is influenza A virus specific antibody, it will combine with the pre-coated antigen, discard the uncombined antibody and other components with washing; then add enzyme labled anti-Influenza A virus monoclonal antibody, antibody in sample block the combination of monoclonal antibody and pre-coated antigen; discard the uncombined enzyme conjugate with washing; Add TMB substrate in micro-wells, the blue signal by Enzyme catalysis is in inverse proportion of antibody content in sample, use ELISA reader at 450nm wavelenth to measure the absorbance A value in reaction wells after adding stop solution to stop the reaction.

2. Reagents and contents

Code Item Spec. Code Item Spec.
1 Antigen Coated plates 96 wells 2 plates 6 Stop solution 15 ml
2 Enzyme Conjugate 22ml 7 Negative control 2 ml
3 10XConcentrated Washing buffer 100 ml 8 Positive control 1 ml
4 Substrate 22 ml 9 Adhesive Foil 4 pieces
5 Sample diluent 100 ml 10 Instruction 1 piece

3. Material required not provided

1) Micropipette: 10ul-100ul, 100ul-1000ul.

2) Disposable pipette tips.

3) Graduate: 500ml.

4) Microplate Reader: 96 wells with 450/630nm wavelength.

5) Distilled water or deionized water.

6) Bottle washer or Microplate Washer

4. Sample preparation

Take animal whole blood, get serum by using regular method, the serum should bright and no hemolysis

5. Washing buffer preparation

Return 10X Concentrated washing buffer into room temperature before use, if there is salt crystals, shake to make it dissolved, then dilute it at 10 times with distilled water or deionized water. The diluted washing buffer can store at 4℃ for about 1 week.

6. Notes

1) Return all reagents into room temperature before use, put the reagents at room temperature for at least 1 hour. Shake it evenly before use, and store back to 2-8℃ after usage.

2) Do not mix use reagents from different kits and different lot no., prevent the reagents been polluted when using.

3) Substrate and stop solution may have irritation to skin and eyes, be careful to use.

4) Do not expose Substrate to strong light and avoid contact with the oxidant.

  • Antigen coated plates should be sealed and moisture-proof. Put back unused Micro-Well plate into dry foil bag and sealed at 2-8 ℃.
  • All wastes should be treated well to avoid pollution before discarding.
  • Strict compliance with the operating instructions can get the best results. Pipetting operation, timing, and washing of the whole process must be precise.
  • Antigen Coated plates is disposable, do not repeat use.

7. Test procedure

1) Take the antigen coated plate(the plate can be open and used for several times according to sample quantity each time), for every test, set 1 well for positive control and 2 wells for negative control, positive control and negative control do not need dilute, take 100ul directly and add into its well;

2) Add Sample diluent to reaction wells, 60ul/well, then add serum sample to the reaction wells, 40ul/well, blow and mix evenly(Do not mix use tips)

3) Cover it with Adhesive Foil, incubate at37℃ for 60minutes;

4) Open the adhesive foil, discard the liquid of the well, add diluted washing buffer to each well, 250ul/well, then discard the liquid, repeat the above step for 6 times, at last flap to dry with the absorbent paper;

5) Adding Enzyme Conjugate 100ul/well, Cover it with Adhesive Foil, incubate at 37 for 60 minutes;

6) Open the adhesive foil, discard the liquid of the well, washing for 6 times as step 4), remember at last flap to dry with the absorbent paper;

7) Add substrate, 100ul/well, mix it evenly then cover it with Adhesive Foil, incubate at 37 in dark for 10 minutes;

8) Add stop solution 50ul/well to stop the reaction, measure the result in 10 minutes.

8. Results judgment

Read the OD value with ELISA Reader at 450nm (630nm as reference).

For the assay to be valid:

Negative control (N) OD value > 0.4 ;

Calculate method:

Sample OD value/Average OD value of Negative control=S/N value

Results interpretation

S/N value ≥ 0.4: Negative;

S/N value< 0.4: Positive.

9. Storage and expire date

Store at 2~8℃ in dark, no frozen, expiry date: 12 months.

Shenzhen Lvshiyuan Biotechnology Co., Ltd

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788 Fax 86-755-28938800

Email: info@lsybt.com www.lsybt.com

Contact Details
Shenzhen Lvshiyuan Biotechnology Co.,Ltd

Contact Person: Mrs. Bella Zou

Tel: +86-755-28438788-8030

Fax: 86-755-28938800

Send your inquiry directly to us (0 / 3000)