Shenzhen Lvshiyuan Biotechnology Co.,Ltd

 

Green Earth, Spring from you and me!

Sales & Support
Request A Quote - Email
Select Language
English
Spanish
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsAnimal Disease ELISA Diagnostic kit

LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit

Certification
Good quality Animal Disease ELISA Diagnostic kit for sales
Good quality Animal Disease ELISA Diagnostic kit for sales
I'm Online Chat Now

LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit

China LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit supplier
LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit supplier LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit supplier LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit supplier

Large Image :  LSY-30021-3 Cysticercosis Antibody IgG4 ELISA test kit

Product Details:

Place of Origin: China
Brand Name: Green Spring
Certification: ISO9001&ISO14001&OHSMS18001
Model Number: LSY-30021-3

Payment & Shipping Terms:

Minimum Order Quantity: 1 kit
Price: FOBShenzhen$220/kit
Packaging Details: By foam box with ice to maintain cool storage
Delivery Time: in 3 working days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 500 kits per day
Detailed Product Description
Shelf Life: 12 Months Specifications: 96 Wells/kit Or 96*2 Wells/kit

Cysticercosis Antibody IgG4 ELISA test kit

Catalog No. LSY-30021-3

  • Principle

This kit use indirect enzyme-linked immunoassay (ELISA) to detect Cysticercosis IgG4 antibody in human serum or plasma qualitatively.

 

  • Reagents and contents
Code Item Spec. Code Item Spec.
1 Coated plate 96 wells 7 Stop solution 6 ml
2 Enzyme Conjugate 10 ml 8 Positive control 0.025ml
3 PBST solid washing buffer 2 bags 9 Negative control 0.050ml
4 Substrate diluent 12 ml 10 Sealed bag 1 piece
5 Substrate powder 1 bottle 11 Adhesive Foil 3 pieces
6 Sample diluent 10 ml 12 Instruction sheet 1 piece

 

3. Material required not provided

1) Microplate Reader with 405nm wavelength;

2) 37 ℃ thermostatic device

3) Micropipettes, adjustable.

 

4. Sample requirement

1) This kit only used to testing human serum or plasma.

2) To get the best test result, avoid using sample with severe hemolysis, precipitate, contaminated by bacteria or protein suspension.

3) The serum sample can store at 2-8 ℃ for short term (in 3 days), if for long term, it should be kept at -20℃ or lower, avoid repeated freezing and thawing.

 

5. Test procedure

1) Washing buffer preparation: dissolve every bag of PBST solid washing buffer with 500ml distilled water completely.

2) Add Sample diluent: add 100ul Sample diluent to each well.

3) Adding samples and controls: for sample wells, only add 10ul sample to each well; 2 wells for blank control, only add 10ul sample diluent to each well; 2 wells for negative control, only add 10ul negative control to each well; 2 wells for Positive control, only add 10ul Positive control to each well. Cover plate with adhesive foil, incubate in dark at 37 ℃ for 90 minutes.

4) Washing plate: discard the liquid of the well, fill full with washing buffer to each well, washing for 5 times, be static for 30s for each time; at last time, flap to dry with the absorbent paper.

5) Adding Enzyme Conjugate: Except blank control, add Enzyme Conjugate to each well, 100ul/well, Cover plate with adhesive foil, incubate in dark at 37 ℃ for 90 minutes. Discard liquid of the wells and wash 5 times as described in step 4).

6). Adding substrates: dissolve all Substrate powder with Substrate diluent, mix evenly, add Substrate to each well, 100ul/well. Cover plate with adhesive foil, incubate in dark at 37℃ for 30 minutes.

7). Stop reaction: Add 50ul Stop solution into all wells to stop reaction. Set zero at blank control, read the OD value at ELISA reader 405nm.

 

6. Reference

1) Cut-off Value (COV) = Average OD Value of Negative control X 2.1 (calculate as 0.05 when the OD Value of Negative control < 0.05).

2) Validation judge

Negative control OD value ≤ 0.10 (If more than 0.10, the test is invalid)

Positive control OD value ≥ 0.30 (If less than 0.30, the test is invalid)

 

7. Results interpretation

Sample OD value ≥ COV: Cysticercosis IgG4 antibody positive;

Sample OD value < COV: Cysticercosis IgG4 antibody negative.

Limitation: This kit is for research use only, not for clinical diagnosis.

 

8. Notes

1) MicroWell plate removed from the refrigerated environment should be balanced moisture to dry at room temperature, then can be opened. Put back unused MicroWell plate into dry foil bag and sealed at 2~8 ℃.

2) Before adding reagent, gently shake dropping bottle and mix even the reagent.

3) Screw down the cap after use, don't mix caps between different bottles and don't mix components between different kits.

4) When incubation, it is recommended to use water bath. If no water bath, put at 37℃ incubator.

5) The test kit and any samples should be regarded as the source of infection to properly handle. Stop solution is corrosive, be careful to use.

 

9. Storage and expire date

Store at 2~8℃ in dark, no frozen, expiry date: 6 months.

 

 

Contact Details
Shenzhen Lvshiyuan Biotechnology Co.,Ltd

Contact Person: Mrs. Bella Zou

Tel: +86-755-28438788-8030

Fax: 86-755-28938800

Send your inquiry directly to us (0 / 3000)